Gas Main To Meter Meter To Attic

There are four screws on each of the box s corners.
Gas main to meter meter to attic. Open a knock out on top of the meter box to fit the riser pole width. Always check with your local gas company about lines and meters outside. Where i used to work the regular houses 3 bedroom 2 baths all had 1 4 psi at the meter. 3 feet in any direction to the feature.
A position perpendicular to the pipe indicates a closed valve but you should double check by confirming that the meter is no longer moving when a appliance is using gas. Distance from your home to the main line. Turn off the gas to your house. Restaurants too needed the gas stepped up.
I have a portable generator that has a natural gas conversion kit. The service entrance must not be located within 3 feet of the utility side of the gas meter or within 10 inches of the customer side of the gas meter. Obstructions like a highway or building. The most common gas piping is black steel.
The piping upstream of the gas meter and the meter itself usually are the responsibility of the gas company. The center of the meter must be 44 to 66 inches off the ground. Repairs are 6 to 7 per foot. Section 2 4 2 gas meter set locations pdf 3 3 mb section 2 4 2 d electric and gas meter set separation dimensions and clearances figure 2 19 pdf 3 3 mb section 2 4 2 d gas meter set clearance from building openings figure 2 20 pdf 3 3 mb j 16 gas meter room pdf 123 kb j 95 meter guard design and installation arrangement pdf.
But the large mansions would get a 2 psi regulator. Secure the box to the wall according to manufacturer recommendations. Or maybe he said 15 20 psi. Often the line up to and including the gas meter is installed owned and maintained by the gas company.
Insert the meter box into the riser pipe then secure it with a connector and a locknut of the same size as the pipe used. The valve will be at your gas meter on the side of your house and should shut off entirely with a quarter turn. The cost to run a gas line from an existing connection is 355 to 743 while adding a pipe from the meter is 500 to 2 000. If the service entrance includes the circuit breaker the highest switch may not be more than 79 inches from the ground.
It uses 140 000 btu or 140 cf. I think he said 20 psi. Gas meter regulator vent clearance distance to windows attic vent crawl space vent soffit vent. I would like to make a t connection right after the meter in the output side of the meter 1 1 4 gas line.
A gas company guy once told me that the gas mains in that area were like 20 psi. Gas supplier private company public municipality or co op. Gas line installation costs 12 to 25 per linear foot. The gas company states my meter can handle the additional requirement of the generator along with my other appliances.
Gas meter regulator vent clearance to electrical devices such as switches electrical receptacles power disconnects.